Product Overview
Features & Benets
DURAFire® Oil Igniter
e DURAFire® can be used as a Class 1, Class 2, or Class 3 igniter,
depending on the burner capacity. e DURAFire® is easily installed as a retrot
into most burner types based on its size, capacity, and reliable operation.
e DURAFire® oil igniter consists of ve major components: a guide
tube, an atomizer/head assembly, an oil/air mixture transport tube, a spark rod,
and a stainless steel diuser for pilot stabilization. e guide tube houses the
internals, which are attached to the head and easily removed from the guide
tube for maintenance purposes by releasing a V band retainer, requiring no
tools. Cooling/combustion airow is directed down the guide tube to support
and maintain the primary combustion zone during operation. is controlled
mixture of fuel and air in the primary combustion zone results in a highly
reliable, stable igniter ame. While out of service, airow cools the igniter and
prevents debris from entering the end of the guide tube.
e DURAFire® oil igniter comes standard with Forneys High Energy
Spark Igniter (HESI) as the spark source. e HESI produces a powerful 12-
joule spark approximately three times per second at the primary combustion
zone. e HESI spark tip is a nonfouling, surface-gap tip which is replaceable as
a unit by a threaded connection. e remaining HESI components consist of a
positioning rod, cable and power unit. Optional equipment for the DURAFire®
includes mounting hardware, retraction assembly, hoses and ame detector.
e DURAFire® oil igniter delivers the
most reliable source of energy for main
ame ignition, ame stabilization, and
boiler warm-up.
Class1,2or3oiligniter
Capacity range from 6 to 30 MBtu/hr.
appliCationFlexibility
e protected primary combustion zone
ensures reliable operation in multiple
environments.
easyretroFit
With a diameter of only 4 inches, the
DURAFire® ts most burners.
lowMaintenanCerequireMents
No moving parts, a self-cleaning spark tip
and no tools required to perform periodic
inspection.
reliableignition
95% ignition rate in most applications.
HigHeFFiCienCyairatoMizer
e internal mix atomizer is selected from a
standard set of sizes for each project.
Cooling/CoMbustionair
Low cooling/combustion air requirements.
Durability
Heavy duty material and no moving parts to
wear out.
CoMpatibility
Fits most existing mount tubes minimizing
retrot installation costs.
A UTC Fire & Security Company
Forney Corporation • 3405 Wiley Post Road • Carrollton, TX 75006 • 800-356-7740 • Fax 972-458-6650 • www.forneycorp.com
DuraFire_rev11-2011.indd 1 11/15/2011 3:47:40 PM
Page view 0
1 2

Summary of Contents

Page 1 - DURAFire® Oil Igniter

Product OverviewFeatures & BenetsDURAFire® Oil Igniter e DURAFire® can be used as a Class 1, Class 2, or Class 3 igniter, depending on the burn

Page 2 - Oil Igniter

Pub # 404006-04 Rev 11/2011DURAFire® Oil Igniter SpecicationsFuel: No. 2 oilBTU Rating: 6-30 MBtu/hrAtomization Media: AirFuel Pressure: 60 psig (at

Comments to this Manuals

No comments